Maintenance and Troubleshooting Of UPS Systems and Battery Power Supplies
Acquire maintenance and troubleshooting skills for UPS systems and battery power supplies in this training course. Ensure reliable backup power systems.
City | Start Date | End Date | fees | details |
---|
Course Description
A sudden loss of power will disrupt most business operations and could lead to a company being unable to trade. Where a company regards electrical power as critical then there will be a need for a continuous or back up power system. The installation of a UPS will provide the necessary continuity.There are however problems with these installations when there is a need for maintenance especially the use of by-pass. Power Quality compatibility problems may cause failure, which was the reason for the original UPS installation.
Course Objective
The course is intended to develop knowledge of the need for a UPS, types available, UPS components, batteries, generators and maintenance.
Course Outline
Introduction to the Resilient System
- Introduction
- Regulations
- Critical loads
- Purpose of an Installation
- Compatibility
- Protection and Devices
- UPS or Generator
- Maintenance
What is a UPS?
- UPS Rating
- Parallel systems
- What is available
- Maintenance by-pass
- Off Line systems
- Redundancy
- On Line systems
- Interactive systems
UPS Components
- Transformer methods
- Harmonics
- Invertors
- Twelve pulse rectifier
- Phase control
- Power factor
- Six pulse rectifier
- Static switch
Batteries
- What is a battery?
- Storage and Care
- VLRA
- Choosing a battery size
- Size and location
- Charging
- Configuration
- Battery safety
Generators and Site Planning
If a power failure exceeds the reserve battery capacity the system will fail but using a generator will ensure continuous power. Planning the site and considering the load will ensure a successful installation and careful maintenance planning will ensure reliability.
- Do I need a Generator?
- Environmental Constraints
- Mains failure
- Monitoring power
- UPS Compatibility
- Installing the UPS
- Generator size considerations
- Maintaining the UPS

Code : EPE2
Advanced Generator Maintenance
One Week

Code : EPE9
Certified Control Systems Technician (CCST)
One Week

Code : EPE14
Condition Monitoring Of Power System Equipment
One Week

Code : EPE16
Design Of Electric Switchboards (lV and MV) Only Of Design and Engineering Engineers
One Week

Code : EPE26
Electrical Engineering Practices For Facilities Engineer
One Week

Code : EPE35
Hazardous Area Classification
One Week

Code : EPE38
HT Motors and Protection Methods For Future
One Week

Code : EPE39
Industrial Automation Using PLC
One Week

Code : EPE64
Sizing, Selecting, and Applying Process Control Valves
One Week

Code : EPE65
Solar Power System Theory and Maintenance
One Week